Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 531-534, 2017.
Article in Chinese | WPRIM | ID: wpr-611522

ABSTRACT

Objective To assess the relationships between area strain (AS) and eccentric index (EI) of atherosclerotic plaques as seen by intravascular ultrasonic elastography (IVUSE),and to reveal the effect of EI on the plaques stability.Methods Forty purebred New Zealand rabbits were fed with a high-cholesterol diet;the abdominal aorta endothelium was balloon-injured after 2 weeks;at the end of week 12,2 plaques with moderate echo from each rabbit were chosen for in situ imaging,and 2 consecutive frames near the end-diastole images in situ were used to construct an IVUS elastogram.Results The eccentric plaques showed significantly greater area stain (AS) than the centripetal plaques [4.77(2.92,8.01)% vs 3.27(2.15,4.82)%,P=0.029] with smaller plaque area and plaque burden (P<0.05).The plaque AS was positively correlated with EI (r=0.392,P=0.003).The eccentric plaques showed significantly greater AS in the shoulder than in body [4.98(3.17,8.48)% vs 4.64(2.51,5.92)%,P=0.008].Conclusions The EI is one of influential factors on plaque AS.Eccentric plaques may be more vulnerable than centripetal plaques,especially in the shoulder of eccentric plaques which have greater AS than their body.

2.
Chinese Journal of Medical Imaging Technology ; (12): 1479-1483, 2017.
Article in Chinese | WPRIM | ID: wpr-662135

ABSTRACT

Objective To assess the relationship between plaque burden (PB) and area strain (AS) by intravascular ultrasonic elastography (IVUSE).Methods Forty purebred New Zealand rabbits were fed with a high-cholesterol diet.And the abdominal aorta endothelium was balloon-injured after 2 weeks.At the end of the 12th week,2 plaques with moderate echo from each rabbit were chosen for in situ imaging,and 2 consecutive frames near the end-diastole images in situ were used to construct an IVUS elastogram.Cross-sectional external elastic membrane area (EEMare),lumen area (Lumenarea),plaque area (PA),PB,external elastic membrane volume (EEMvolume),lumen volume (Lumenvolume),plaque volume (PV),plaque volume burden (PVB),maximal plaque thickness (Tmax) and minimal plaque thickness (Tmin),eccentric index (EI),remodeling index (RI) and AS were measured and calculated,respectively.According to the PB,the plaques were divided into low PB group (PB≤40 %) and high PB group (PB> 40 %).The differences of all above parameters between the two groups were compared,and the relationship between the plaque morphological and mechanical parameters were analyzed.Results PA,PV,PB,PVB,Tmin,Tmax,Lumenarea,Lumenvolume and EI were different between the 2 groups (all P<0.01).On stepwise multiple regression analysis,the regression equation were built,(Y)=-6.921+10.430X1 +12.207X2((Y):AS,X1:EI,X2:PB,R2 =0.272,P<0.001).After eliminating the effect of EI on the AS,the lower PB group had obviously smaller AS than higher PB group (P =0.010).Conclusion The PB has effect on plaque mechanical stability.The plaques with higher burden are more vulnerable than those with lower burden.

3.
Chinese Journal of Medical Imaging Technology ; (12): 1479-1483, 2017.
Article in Chinese | WPRIM | ID: wpr-659462

ABSTRACT

Objective To assess the relationship between plaque burden (PB) and area strain (AS) by intravascular ultrasonic elastography (IVUSE).Methods Forty purebred New Zealand rabbits were fed with a high-cholesterol diet.And the abdominal aorta endothelium was balloon-injured after 2 weeks.At the end of the 12th week,2 plaques with moderate echo from each rabbit were chosen for in situ imaging,and 2 consecutive frames near the end-diastole images in situ were used to construct an IVUS elastogram.Cross-sectional external elastic membrane area (EEMare),lumen area (Lumenarea),plaque area (PA),PB,external elastic membrane volume (EEMvolume),lumen volume (Lumenvolume),plaque volume (PV),plaque volume burden (PVB),maximal plaque thickness (Tmax) and minimal plaque thickness (Tmin),eccentric index (EI),remodeling index (RI) and AS were measured and calculated,respectively.According to the PB,the plaques were divided into low PB group (PB≤40 %) and high PB group (PB> 40 %).The differences of all above parameters between the two groups were compared,and the relationship between the plaque morphological and mechanical parameters were analyzed.Results PA,PV,PB,PVB,Tmin,Tmax,Lumenarea,Lumenvolume and EI were different between the 2 groups (all P<0.01).On stepwise multiple regression analysis,the regression equation were built,(Y)=-6.921+10.430X1 +12.207X2((Y):AS,X1:EI,X2:PB,R2 =0.272,P<0.001).After eliminating the effect of EI on the AS,the lower PB group had obviously smaller AS than higher PB group (P =0.010).Conclusion The PB has effect on plaque mechanical stability.The plaques with higher burden are more vulnerable than those with lower burden.

4.
Chongqing Medicine ; (36): 5082-5083,5086, 2015.
Article in Chinese | WPRIM | ID: wpr-603097

ABSTRACT

Objective To explore the clinical values of holter among different types of pacemaker postoperations .Methods Selected 120 patients undergoing pacemaker implantation from November 2013 to October 2014 ,who also received holter examina-tion after operation .The sensing and pacing dysfunction and pacemaker associated arrhythmia were analyzed according to their hol-ter results .Results In the DDD group ,the detection rate of the ventricular premature contraction ,the atrial premature contraction , the paroxysmal atrial tachycardia ,the paroxysmal atrial fibrillation and the paroxysmal supraventricular tachycardia were 38 .9% , 44 .4% ,8 .3% ,2 .8% and 2 .8% ,respectively .In the DDD group ,the detection rate of the sensing and pacing dysfunction and pace-maker associated arrhythmia was 69 .4% ,which was significantly higher ( P < 0 .05) than that in the VVI group (42 .5% ) ,the VVIR group(30 .0% ) ,the DDDR group(31 .3% ) and the AAI group(25 .0% ) ,respectively .In the VVI group ,the positive rate of the ventricular premature contraction ,the atrial premature contraction ,the paroxysmal atrial tachycardia ,the paroxysmal atrial fi-brillation and the paroxysmal supraventricular tachycardia were 37 .5% ,42 .5% ,10 .0% ,17 .5% and 2 .5% ,respectively .In the VVIR group ,the appearance rate of the ventricular premature contraction ,the atrial premature contraction and the paroxysmal atrial tachycardia were 25 .0% ,25 .0% and 5 .0% ,respectively .In the DDDR group ,the detectable rate of the ventricular premature con-traction ,the atrial premature contraction ,the paroxysmal atrial tachycardia and the paroxysmal atrial fibrillation were 31 .3% , 25 .0% ,12 .5% and 12 .5% ,respectively .Finally ,in the AAI group ,the detection rate of the ventricular premature contraction and the atrial premature contraction were 25 .0% each .Conclusion The clinical application of holter can evaluate the working states of different types of pacemakers ,and can monitor the sensing ,the pacing dysfunction and the pacemaker associated arrhythmia .

5.
Journal of Biomedical Engineering ; (6): 1170-1174, 2011.
Article in Chinese | WPRIM | ID: wpr-274932

ABSTRACT

The present study was to investigate in vitro the rat cardiomyocyte injury with targeting of home-made perfluorocarbon lipid particles with avidin-biotin interaction. Neonatal rat cardiomyocytes were cultured in vitro and divided into two groups: TNF-alpha activated group and non-activated group. Those in the TNF-alpha activated group were exposed to 200 ng/ml TNF-alpha solution for 6 hours and then cardiomyocytes in both groups were pretargeted with biotinylated ICAM-1 monoclonal antibodies, and were exposed to streptavidin, and then to homemade green fluorescently-labeled biotinylated perfluorocarbon lipid particles. Cardiomyocytes nucleus stained with Hoechst. The results were detected with fluorescence microscope. As a result, in TNF-alpha activated group, around blue fluorescent cardiomyocytes nucleus, a great amount of green fluorescent particles were found, while there were few green fluorescent particles in non-TNF activated group. It has been shown that ICAM-1 is expressed in the surface of cardiomyocytes when they are stimulated by TNF-alpha. Perfluorocarbon lipid particles associated with ICAM-1 monoclonal antibodies can be targeted to injured cardiomyocytes by avidin-biotin interaction.


Subject(s)
Animals , Female , Male , Rats , Animals, Newborn , Antibodies, Monoclonal , Metabolism , Cells, Cultured , Contrast Media , Fluorocarbons , Allergy and Immunology , Metabolism , Intercellular Adhesion Molecule-1 , Metabolism , Lipids , Chemistry , Microspheres , Myocytes, Cardiac , Metabolism , Pathology , Rats, Sprague-Dawley , Tumor Necrosis Factor-alpha , Pharmacology , Ultrasonography
6.
Chinese Journal of Ultrasonography ; (12): 369-373, 2010.
Article in Chinese | WPRIM | ID: wpr-389672

ABSTRACT

Objective To evaluate left ventricular torsion and untwisting in patients with coronary artery disease by speckle tracking imaging. Methods Study population consisted of 48 patients, who were diagnosed coronary artery disease initially and received one of coronary arteriography, coronary artery spiral computerized tomography, radionuclide imaging, interventional therapy and bypass surgery. High frame rate (≥60 frame/s) two-dimensional dynamic images of the left ventricular apical long-axis views and parasternal short-axis views at basal and apical levels were recorded. Rotation was measured in the left ventricular short-axis views using 2D strain software. Left ventricular torsion was defined as relative rotation degree between the apical level and basal level. Patients were divided into three groups according to clinic final diagnosis [myocardial infarction ( MIN) group, n = 19; myocardial ischemia ( MIS) group, n =19; normal coronary artery (Contrast) group, n - 10]. Results In MIS group,peak rotation value and rotation value at aortic valve closure in basal level were smaller than those in apical level. Untwisting rate reduced in MIN group. There was linear correlation between left ventricular peak torsion and end-diastolic diameter. There was aslo linear correlation between left ventricular peak torsion and eject fraction. Left ventricular peak rotation at basal level was correlative to eject fraction. Left ventricular untwisting rate had linear correlation to eject fraction, and also had correlation to peak torsion. Conclusions In patients with myocardial ischemia, left ventricular rotation value at apical level is larger than that at basal level. Left ventricular diastolic function is injured severely in patients with myocardial infarction. Untwisting rate is a quantitative index to evaluate myocardial diastolic function.

7.
Chinese Journal of Ultrasonography ; (12): 1030-1033, 2009.
Article in Chinese | WPRIM | ID: wpr-391881

ABSTRACT

Objective To research the feasibility and accuracy on echocardiography measurement aortic annulus diameter(AAD)at the plane of three Junctions of aortic valve leaflets by real-time three-dimensional transesophageal echocardiography(RT-3D-TEE).Methods Twenty-three patients underwent echocardiography and aortic valve replacement because of acquired aortic valve disease.The AAD was measured in parasternal left ventricle long axis view(TTE-AAD)by transthoracic echocardiography(TTE)preoperative.The AAD was measured in left ventricle long axis view(TEE-AAD)and the distance of three iunctions of aortic valve leaflets (N,L,R) was measured in aortic short axis view by RT-3D-TEE intraoperative.The three-dimensional full volume images were analyzed by online QLAB 7.0 software.The AAD was measured by standard cylindrical valve sizer (OP-AAD)before aortic valve replacement surgery,too.Results Comparing with the three aortic valve leaflets of acquired aortic valve disease,the lines between their junctions constituted an approximate equilateral triangle regardless of the cause and degree of disease,and the length of the three groups was no significant difference(P>0.05).There was no significant difference between TTE-AAD and OP-AAD group(P>0.05),and the correlation was good(r=0.84).The N,L and R group compared separately with the OP-AAD group, there was no significant difference(P>0.05)and correlation was superior to TTE-AAD group(r=0.94, 0.97, 0.96).The difference between TEE-AAD and OP-AAD were significant(P<0.01).Conclusions Echocardiography measurement of AAD at the plane of three junctions of aortic valve leaflets is feasible,and it is better accuracy and repeatability comparing with parasternal left ventricle long axis view.

SELECTION OF CITATIONS